New monitor watches the behavior of all electric devices within a building, ship, or factory

Photo shows the area on the Coast Guard cutter Spencer’s diesel engine where the MIT-developed “NILM Dashboard” detected damage that could have caused a fire. The damage was hidden under the brown cap at center.
Image courtesy of the researchers

Sensor can monitor wiring in a building or ship, and signal when repairs are needed.

A new system devised by researchers at MIT can monitor the behavior of all electric devices within a building, ship, or factory, determining which ones are in use at any given time and whether any are showing signs of an imminent failure. When tested on a Coast Guard cutter, the system pinpointed a motor with burnt-out wiring that could have led to a serious onboard fire.

The new sensor, whose readings can be monitored on an easy-to-use graphic display called a NILM (non-intrusive load monitoring) dashboard, is described in the March issue of IEEE Transactions on Industrial Informatics, in a paper by MIT professor of electrical engineering Steven Leeb, recent graduate Andre Aboulian MS ’18, and seven others at MIT, the U.S. Coast Guard, and the U.S. Naval Academy. A second paper will appear in the April issue of Marine Technology, the publication of the Society of Naval Architects and Marine Engineers.

The system uses a sensor that simply is attached to the outside of an electrical wire at a single point, without requiring any cutting or splicing of wires. From that single point, it can sense the flow of current in the adjacent wire, and detect the distinctive “signatures” of each motor, pump, or piece of equipment in the circuit by analyzing tiny, unique fluctuations in the voltage and current whenever a device switches on or off. The system can also be used to monitor energy usage, to identify possible efficiency improvements and determine when and where devices are in use or sitting idle.

The technology is especially well-suited for relatively small, contained electrical systems such as those serving a small ship, building, or factory with a limited number of devices to monitor. In a series of tests on a Coast Guard cutter based in Boston, the system provided a dramatic demonstration last year.

About 20 different motors and devices were being tracked by a single dashboard, connected to two different sensors, on the cutter USCGC Spencer. The sensors, which in this case had a hard-wired connection, showed that an anomalous amount of power was being drawn by a component of the ship’s main diesel engines called a jacket water heater. At that point, Leeb says, crewmembers were skeptical about the reading but went to check it anyway. The heaters are hidden under protective metal covers, but as soon as the cover was removed from the suspect device, smoke came pouring out, and severe corrosion and broken insulation were clearly revealed.

“The ship is complicated,” Leeb says. “It’s magnificently run and maintained, but nobody is going to be able to spot everything.”

Lt. Col. Nicholas Galanti, engineer officer on the cutter, says “the advance warning from NILM enabled Spencer to procure and replace these heaters during our in-port maintenance period, and deploy with a fully mission-capable jacket water system. Furthermore, NILM detected a serious shock hazard and may have prevented a class Charlie [electrical] fire in our engine room.”

The system is designed to be easy to use with little training. The computer dashboard features dials for each device being monitored, with needles that will stay in the green zone when things are normal, but swing into the yellow or red zone when a problem is spotted.

Detecting anomalies before they become serious hazards is the dashboard’s primary task, but Leeb points out that it can also perform other useful functions. By constantly monitoring which devices are being used at what times, it could enable energy audits to find devices that were turned on unnecessarily when nobody was using them, or spot less-efficient motors that are drawing more current than their similar counterparts. It could also help ensure that proper maintenance and inspection procedures are being followed, by showing whether or not a device has been activated as scheduled for a given test.

“It’s a three-legged stool,” Leeb says. The system allows for “energy scorekeeping, activity tracking, and condition-based monitoring.” But it’s that last capability that could be crucial, “especially for people with mission-critical systems,” he says. In addition to the Coast Guard and the Navy, he says, that includes companies such as oil producers or chemical manufacturers, who need to monitor factories and field sites that include flammable and hazardous materials and thus require wide safety margins in their operation.

One important characteristic of the system that is attractive for both military and industrial applications, Leeb says, is that all of its computation and analysis can be done locally, within the system itself, and does not require an internet connection at all, so the system can be physically and electronically isolated and thus highly resistant to any outside tampering or data theft.

Although for testing purposes the team has installed both hard-wired and noncontact versions of the monitoring system — both types were installed in different parts of the Coast Guard cutter — the tests have shown that the noncontact version could likely produce sufficient information, making the installation process much simpler. While the anomaly they found on that cutter came from the wired version, Leeb says, “if the noncontact version was installed” in that part of the ship, “we would see almost the same thing.”

See Also

Learn more: Energy monitor can find electrical failures before they happen

 

The Latest on: Non-intrusive load monitoring

[google_news title=”” keyword=”non-intrusive load monitoring” num_posts=”10″ blurb_length=”0″ show_thumb=”left”]

via Google News

 

The Latest on: Non-intrusive load monitoring
  • Novibet strengthens AML grip with new W2 tool by FullCircl
    on May 8, 2024 at 5:10 am

    Online bookmaker Novibet has inked a new partnership with ID specialist FullCircl for the onboarding of the latter’s digital compliance tool W2.

  • Silicon Laboratories Inc. (NASDAQ:SLAB) Q1 2024 Earnings Call Transcript
    on April 25, 2024 at 8:09 am

    April 24, 2024 Silicon Laboratories Inc. misses on earnings expectations. Reported EPS is $-1.77142 EPS, expectations were $-0.98. SLAB isn't one of the 30 most popular stocks among hedge funds at the ...

  • Silicon Laboratories Inc. (SLAB) Q1 2024 Earnings Call Transcript
    on April 24, 2024 at 12:17 pm

    Additionally, during our call today, we will refer to certain non-GAAP financial information. A reconciliation of our GAAP to non-GAAP results is included in the company's earnings press release ...

  • Top 5 Best Non-Wifi Baby Monitors 2024
    on April 24, 2024 at 1:28 am

    Having done research and tried out a number of non-Wi-Fi baby monitors, I came up with the best products that parents may rely on to monitor their baby in a secure and safe way. In this article ...

  • The best gaming monitor 2024
    on April 19, 2024 at 7:43 am

    Picking up the best gaming monitor is a sure fire way to enhance your setup. With plenty of options out there to fit a variety of playstyles, if can be tricky pinpointing the right panel for your ...

  • New Perspectives on Viral Load Monitoring of Antiretroviral Therapy
    on April 8, 2024 at 5:00 pm

    Measurement of plasma HIV RNA (plasma viral load, VL) reveals the reason for ... For the current study, both Roche PCR Amplicor Monitor assay (PCR, threshold 400 copies/ml) or the Roche ...

  • Real Time Non-intrusive Debugging Framework
    on April 1, 2024 at 5:00 pm

    This paper briefly discusses a low cost non-intrusive debugging methodology, specifically focus on the timing critical environment. Real time monitoring is the key consideration; other key ...

  • How age-tech can radically improve healthcare for senior citizens
    on December 19, 2023 at 8:50 pm

    Age-tech must be totally non-intrusive: It is a paradox when you ... Age-tech can reduce load on hospitals: By building sophisticated remote patient monitoring systems, people may not have to visit ...

  • Master's students
    on April 16, 2021 at 7:24 pm

    Her research is focused on developing machine learning in the field of Non-intrusive Load Monitoring. Her research interests are machine learning, data science and signal processing techniques. Ashraf ...

  • Use your TV as a computer monitor: Everything you need to know
    on June 13, 2017 at 2:19 pm

    You’re not the first person who’s wondered what it would be like to have a giant desktop monitor. Think of all ... Some HDTVs have non-standard resolutions; it’s not a given that your ...

via  Bing News

 

What's Your Reaction?
Don't Like it!
0
I Like it!
0
Scroll To Top