The Chem-Phys patch monitors both biochemical and electric signals in the human body at the same time — a first
Engineers at the University of California San Diego have developed the first flexible wearable device capable of monitoring both biochemical and electric signals in the human body. The Chem-Phys patch records electrocardiogram (EKG) heart signals and tracks levels of lactate, a biochemical that is a marker of physical effort, in real time. The device can be worn on the chest and communicates wirelessly with a smartphone, smart watch or laptop. It could have a wide range of applications, from athletes monitoring their workouts to physicians monitoring patients with heart disease.
Nanoengineers and electrical engineers at the UC San Diego Center for Wearable Sensors worked together to build the device, which includes a flexible suite of sensors and a small electronic board. The device also can transmit the data from biochemical and electrical signals via Bluetooth.
Nanoengineering professor Joseph Wang and electrical engineering professor Patrick Mercier at the UC San Diego Jacobs School of Engineering led the project, with Wang’s team working on the patch’s sensors and chemistry, while Mercier’s team worked on the electronics and data transmission. They describe the Chem-Phys patch in the May 23 issue of Nature Communications.
“One of the overarching goals of our research is to build a wearable tricorder-like device that can measure simultaneously a whole suite of chemical, physical and electrophysiological signals continuously throughout the day,” Mercier said. “This research represents an important first step to show this may be possible.”
Most commercial wearables only measure one signal, such as steps or heart rate, Mercier said. Almost none of them measure chemical signals, such as lactate.
That is the gap that the sensor designed by researchers at the Jacobs School of Engineering at UC San Diego aims to bridge. Combining information about heart rate and lactate–a first in the field of wearable sensors–could be especially useful for athletes wanting to improve their performance. Both Mercier and Wang have been fielding inquiries from Olympic athletes about the technologies the Center for Wearable Sensors produces.
“The ability to sense both EKG and lactate in a small wearable sensor could provide benefits in a variety of areas,” explained Dr. Kevin Patrick, a physician and director of the Center for Wireless and Population Health Systems at UC San Diego, who was not involved with the research. “There would certainly be interest in the sports medicine community about how this type of sensing could help optimize training regimens for elite athletes,” added Patrick, who is also a member of the Center for Wearable Sensors. “The ability to concurrently assess EKG and lactate could also open up some interesting possibilities in preventing and/or managing individuals with cardiovascular disease.”
The researchers’ biggest challenge was making sure that signals from the two sensors didn’t interfere with each other. This required some careful engineering and a fair bit of experimentation before finding the right configuration for the sensors.
Making the patch
Researchers used screen printing to manufacture the patch on a thin, flexible polyester sheet that can be applied directly to the skin. An electrode to sense lactate was printed in the center of the patch, with two EKG electrodes bracketing it to the left and the right. Engineers went through several iterations of the patch to find the best distance between electrodes to avoid interference while gathering the best quality signal. They found that a distance of four centimeters (roughly 1.5 inches) between the EKG electrodes was optimal.
Researchers also had to make sure the EKG sensors were isolated from the lactate sensor. The latter works by applying a small voltage and measuring electric current across its electrodes. This current can pass through sweat, which is slightly conductive, and can potentially disrupt EKG measurements. So the researchers added a printed layer of soft water-repelling silicone rubber to the patch and configured it to keep the sweat away from the EKG electrodes, but not the lactate sensor.
The sensors were then connected to a small custom printed circuit board equipped with a microcontroller and a Bluetooth Low Energy chip, which wirelessly transmitted the data gathered by the patch to a smartphone or a computer.
Testing
The patch was tested on three male subjects, who wore the device on their chest, near the base of their sternum, while doing 15 to 30 minutes of intense activity on a stationary bike. Two of the subjects also wore a commercial wristband heart rate monitor. The data collected by the EKG electrodes on the patch closely matched the data collected by the commercial wristband. The data collected by the lactate biosensor follows closely data collected during increasing intensity workouts in other studies.
Next steps
Next steps include improving the way the patch and the board are connected and adding sensors for other chemical markers, such as magnesium and potassium, as well as other vital signs. Physicians working with Wang and Mercier are also excited about the possibility of analyzing the data from the two signals and see how they correlate.
Learn more: Engineers take first step toward flexible, wearable, tricorder-like device
The Latest on: Wearable sensors
[google_news title=”” keyword=”Wearable sensors” num_posts=”10″ blurb_length=”0″ show_thumb=”left”]
via Google News
The Latest on: Wearable sensors
- Wearable Devices Invited to Present its Gesture Control Technology to Samsung's Senior Management in South Koreaon May 2, 2024 at 6:23 am
"The Samsung Global Sourcing Fair is a renowned event that brings together the brightest minds and the most innovative technologies units at Samsung”, said Asher Dahan, Chief Executive Officer of ...
- Wearable exoskeleton can turn you into superhuman athleteon May 2, 2024 at 3:00 am
The X1 exoskeleton is a motorized artificial intelligence-powered all-terrain device that straps to your waist and thighs for hiking climbing and running.
- Medical Sensors Market worth $3.6 billion by 2029 - Exclusive Report by MarketsandMarkets™on May 1, 2024 at 7:13 am
The medical sensors market is valued at USD 2.4 billion in 2024 and is projected to reach USD 3.6 billion by 2029; it is expected to grow at a CAGR of 8.1% from 2024 to 2029 according to a new report ...
- Flexible Sensor Market to Reach $11.2 Billion Globally by 2032 at 7.7% CAGR: Allied Market Researchon April 30, 2024 at 2:55 am
The rising popularity of wearable devices and continuous technological advancements are projected to drive the global flexible sensor market's growth during the forecast period from 2032 to 2032. The ...
- Wearable Sensors Market towards a USD 10.19 Billion by 2032on April 29, 2024 at 11:15 pm
IntroductionAccording to Market.us, The Global Wearable Sensors market size is expected to be worth around USD 10.19 Billion by 2032, from USD 3.55 Billion in 2023, growing at a CAGR of 12.8% during ...
- This new wearable AC from Sony can help you beat the heat this summeron April 29, 2024 at 10:58 pm
Sony's Reon Pocket 5, a wearable air conditioner, provides comfort through cooling and heating. Equipped with a thermo module, sensors, Reon Pocket ta ...
- Wearable Sensors Market Outlook, Size, Prominent Players, Share, Revenue, and Forecast 2024 to 2032on April 28, 2024 at 3:09 pm
Report Ocean has recently unveiled its research findings on the “Wearable Sensors Market” spanning from 2024 to 2032. This comprehensive report thoroughly analyzes the market dynamics, including ...
- Wearable Technology During Surgery Provides Neurosurgeons With Postural Infoon April 24, 2024 at 11:30 pm
Wearable technology is feasible to assess postural ergonomics and provide objective biofeedback to neurosurgeons, according to a pilot study published online April 19 in the Journal of Neurosurgery: ...
- Wearable Sensors Market towards a USD 10.19 billion in 2032on April 22, 2024 at 7:45 am
IntroductionThe global wearable sensors market is poised for significant growth, projected to reach a value of USD 10.19 billion by 2032, with a steady Compound Annual Growth Rate (CAGR) of 12.8% ...
- I’ve seen the future, and it’s really salty: Testing Flowbio’s new wearable hydration sensoron April 22, 2024 at 5:31 am
The sold-out sensor already has WorldTour adoption, but given time it could become as ubiquitous as the heart rate monitor ...
via Bing News