Frequent measurement of blood flow changes could improve the ability of health care providers to diagnose and treat patients with vascular conditions, such as those associated with diabetes and high blood pressure.
A U.S.-Chinese team that included researchers from the National Institute of Biomedical Imaging and Bioengineering(NIBIB) and the National Heart, Lung, and Blood Institute, both parts of the National Institutes of Health, conducted a pilot study showing that an ultrathin, skin-conforming sensor—resembling a peel-away tattoo—provides non-invasive, precise, and continuous monitoring of circulation, including blood flow within the smallest vessels.
In a study published in the Oct. 30, 2015 issue of Science Advances, the researchers showed that the sensor can measure blood flow in both large and micro-sized blood vessels near the skin’s surface. They also provided details about the design and operation of the device. The researchers assessed the sensor’s performance under various conditions, showing that the technology could be used for continuous blood-flow monitoring during daily activities and in a variety of clinical research and health care settings.
In addition to diabetes and chronic hypertension, conditions that affect the health of blood vessels and surrounding tissue include kidney disease, autoimmune and other inflammatory conditions, the effects of aging and smoking, and a class of cholesterol-related abnormalities called dyslipidemias. Continuous monitoring of variations in blood flow could also be valuable in assessing these conditions in clinical and research scenarios.
The pilot-tested device, which was co-developed with researchers at Northwestern University, is among a variety of tools available to measure blood flow. Other devices, such as ones based on optical or acoustic methods, however, do not work as well when the body is in motion, and thus require a patient or study subject to remain still.
The researchers overcame these challenges with the soft, skin-conforming electronic device that is applied directly onto the skin and uses thermal sensors to collect data on changes in temperature, including those caused by changes in blood flow. The device can also apply a small amount of heat in order to test a subject’s responses. In this mode, a miniature pad in the device generates a heat impulse, while 14 surrounding thermal sensors detect the resulting heat flux. The signal is sent to a computer that calculates the velocity of blood flow occurring within two millimeters of the skin surface.
In their study, the researchers placed the sensor on a study subject’s forearm, over a large, visible vein, and then applied pressure for 60 seconds at various positions near the vein. Each time, the device sensed corresponding reductions in blood flow. The researchers also used a thermal camera that measures infrared signals to confirm that the blood-flow sensor measurements were accurate, even when the subject moved around.
Next, they chose a placement on the forearm that was not near a large vein, so that the device would detect blood flow in micro-sized blood vessels within the underlying tissue. The researchers were able to detect changes in blood flow when the study subject took a deep breath. Members of the team at a collaborating institution performed a separate test that involved delivering a gentle slap to the skin near the electronic sensor, which caused a mild reddening reaction. The sensor registered the skin reaction as an increase of surface temperature, accompanied by a change in the direction of blood flow within two millimeters of the skin’s surface.
According to co-author Alexander Gorbach, Ph.D., head of NIBIB’s Infrared Imaging and Thermometry Unit, the tests performed with the thermal sensor helped to establish a number of guidelines for its use, such as optimal placement of the sensor, and how deeply under the skin’s surface the device can assess blood flow. At this stage, the device shows promise as a low-cost, readily-fabricated sensor for use in ambulatory or hospital-based settings. Because of the link between chronic hypertension and some types of vascular diseases, the new sensor may be a useful addition to studies of hypertension and its consequences.
Read more: NIBIB researchers help design and test blood-flow sensor for vascular disease monitoring
The Latest on: Vascular disease monitoring
[google_news title=”” keyword=”vascular disease monitoring” num_posts=”10″ blurb_length=”0″ show_thumb=”left”]
via Google News
The Latest on: Vascular disease monitoring
- Rare genetic condition may offer protection from heart diseaseon April 30, 2024 at 3:56 pm
A rare genetic condition, known as growth hormone receptor deficiency (GHRD) or Laron syndrome, may protect against cardiovascular disease.
- Burn pits increased risk of asthma, heart problems, new DOD data showson April 30, 2024 at 11:41 am
Researchers tracked nearly 460,000 veterans and found increased risk of several respiratory and heart issues among individuals who deployed near burn pits.
- Demand for Innovative Solutions in Managing Peripheral Artery Disease: Skin Perfusion Pressure Testing Market Set to Expand at a 4.5% CAGR by 2030on April 29, 2024 at 7:13 pm
According to recent market projections, the global skin perfusion pressure testing devices market, crucial tools in diagnosing and managing PAD, is anticipated to experience a steady growth of 4.5% ...
- MSU researcher develops new, affordable detection and monitoring methods for cardiovascular diseaseon April 29, 2024 at 6:32 pm
A Mississippi State University researcher is developing new, more affordable methods for early detection and monitoring of cardiovascular disease, the leading cause of death in the U.S.
- Novel Insights Into Renal, Cardiovascular, and Metabolic Outcomes From the CVOT Summiton April 29, 2024 at 6:34 am
The following is a summary of the “CVOT Summit Report 2023: new cardiovascular, kidney, and metabolic outcomes,” published in the March 2024 issue of Cardiology by Schnell et al. The 9th ...
- Study finds artery stiffness indicative of cardiovascular riskon April 29, 2024 at 4:37 am
Cardiovascular diseases represent the leading cause of death worldwide. Preventing cardiovascular risk by identifying the people most susceptible to these diseases is a major public health challenge.
- APCCC 2024: Cardiovascular Complications in Advanced Prostate Cancer – How to Prevent Them and How to Monitor Patients?on April 27, 2024 at 7:58 am
Advanced Prostate Cancer Consensus Conference (APCCC) meeting featured a session on the identification, assessment, and management of side effects of systemic therapies, and a presentation by Dr.
- Type 2 diabetes may increase risk of extracranial large artery disease: Lanceton April 26, 2024 at 9:00 pm
A recent comprehensive study published in The Lancet Regional Health - Europe identified a significant decline in the incidence of peripheral arterial complications among the individuals with ...
- HOPE-CAT Can Identify Maternal Cardiovascular Risk 2 Months Earlier Than Doctors, Study Sayson April 25, 2024 at 6:10 am
In a retrospective study, the machine learning tool was able to screen for potential risks of cardiovascular disease nearly 60 days before the patient's medical record showed any signs of a related ...
- Leveling the field: MSU researcher develops new, affordable detection and monitoring methods for cardiovascular diseaseon April 22, 2024 at 9:25 am
A Mississippi State University researcher is developing new, more affordable methods for early detection and monitoring of cardiovascular disease, the leading cause of death in the U.S.
via Bing News